Warning! Unfortunately your browser has disabled scripting. Please enable it in order to display this page.
 

1,3,6,8-Tetrabromo-9H-carbazole Certified Reference Standard | Wellington Laboratories | Greyhound Chromatography

1,3,6,8-Tetrabromo-9H-carbazole Certified Reference Standard

     Polar Bear Cub         Wellington Laboratories Logo

 

Halogenated carbazoles have recently been recognised as emerging environmental contaminants. Although there exact source has not been determined, both modern and historic sources (LED manufacturing and halogenated indigo dyes respectively) have been suggested. Since certain halogenated carbazole congeners can be lost during acid silica clean-up, it is very important that reference standards be used to monitor recoveries when processing samples.

1,3,6,8-Tetrabromo-9H-carbazole Certified Reference Standard - Buy online HERE

For over 30 years Greyhound Chromatography has been supplying high quality Chromatography consumables to laboratories around the world. Greyhound’s extensive range covers all areas of Environmental, Petrochemical, Food, Forensics, Chemical and Pharmaceutical analysis. Backed by a highly experienced technical services team, Greyhound is the preferred source amongst today’s analysts.

Greyhound Chromatography is pleased to supply Wellington Laboratories Certified Reference Standards and Materials to Research and Analysis laboratories worldwide.

You May also be Interested in

Agilent Certified, pre-assembled screw top vial pack, 2 mL, clear vials, PTFE/red rubber septa, blue caps

 

Agilent Technologies Logo

Genuine Agilent Part: 5182-0553


Description
Agilent Certified, pre-assembled screw top vial pack, 2 mL, clear vials, PTFE/red rubber septa, blue caps, 100/pk

 

Agilent Flash lamp for G1321A

Agilent Technologies Logo

Genuine Agilent Part: 2140-0600


Description
Agilent Flash lamp for G1321A fluorescence detector

Agilent Snap top vial, 2 mL, amber with write-on spot

                                  Agilent Snap top vial, 2 mL, amber with write-on spot

Genuine Agilent Part: 5182-0545


Description

Agilent Snap top vial, 2 mL, amber with write-on spot, 100/pk

 

View the full range of Greyhound Syringe Filters 

Regenerated Cellulose Syringe Filters

Q-Fil Certified Syringe Filters

Q-Fil Certified Syringe Filters set the new Quality standard for today’s laboratory syringe filters Manufactured from the highest quality medical grade high density polypropylene, Q-Fil Certified Syringe Filters provide excellent chemical compatibility with acids, alcohols, bases, ethers, glycols, ketones and oils, with maximum operating temperatures of 135°C.

Every colour-coded filter is printed with the individual batch number, details of the membrane material and its pore size, on the outside rim of the filter, making them unique for traceability, GLPs and validation purposes.

BUY HERE

Colour coded Syringe Filters

Why filter your samples for HPLC?

• To protect the HPLC column, the column inlet frits and capillary columns against blockage (plugging) caused by particulate matter in the sample
• To protect injection valves from damage caused by scratching and wear of the valves internal components, caused by harmful particulate matter in the unfiltered sample, thereby reducing instrument downtime.

 

About our Quality Control procedures

• Every batch of filters is tested by an independent laboratory to ISO 17025 quality procedures

• Every individual Q-Fil Certified Syringe Filter is visually inspected to ensure it meets our manufacturing and quality control specifications
• Samples of all our syringe filters and their respective raw technical data are stored for a period of 5 years from the date of manufacture for future reference
• Each batch of filters is tested prior to release for
- External Dimensions
- Bubble Point
- Burst Pressure
- Filter Integrity
- Water Flow Rate
- UV Extractables and compliance with all technical procedures

 

Why use Greyhound Q-Fil Certified Syringe Filters?

• Q-Fil Certified Syringe Filters are manufactured in compliance with ISO 9001:2000 quality procedures

• Every box is supplied with a Certificate of Analysis and Conformance to guarantee its batch to batch quality and performance
• The unique encapsulating process developed for these filters, forces the sample to pass only through the membrane, thus avoiding the possibility of leaks or contamination
• Available in the most popular sizes, porosities and membrane types
• Excellent resistance to all routinely used HPLC solvents
• Filter housings are manufactured from high density medical grade polypropylene
• Extremely low level of extractables for highly sensitive work
• Luer connections fully comply with ISO 594-1
• Filters are available with standard and ‘SlimTip’ sized outlets

 

Selecting the right Q-Fil Certified Syringe Filter

• Choose the size of filter based on the volume of sample to be filtered

• Choose the filters porosity based on the size of the potential particulates in the sample. It is important to be aware that the finer the porosity of the membrane the greater the pressure will be required to pass the sample through the filter. A sample containing large quantities of particulates is best filtered using a filter with a built-in glass fibre pre-filter
• Choose the type of membrane based on the solvent being filtered.


Filter Sizes


All our filters have female Luer Lock inlets and are available in three diameters -

25mm Diameter
Designed for large sample volumes or solvent filtration
Wide cross sectional area 3.55cm2
Maximum filtration volume >10ml
Maximum operating pressure 550 Kpa

13mm Diameter
Suitable for most applications
Filtration area of 0.95cm2
Maximum filtration volume 1 to 10ml Maximum operating pressure 750 Kpa Now available with ‘SlimTip’ (ST) outlet

4mm Diameter
Suitable for most applications Ideal for small samples <1ml Pore sizes of 0.20µm and 0.45µm
SlimTip Filters (ST)
13mm diameter syringe filters are now available with the new ‘SlimTip’ outlet for direct filling of microvials.

 

Pore Sizes


Q-Fil Certified Syringe Filters are available in 0.20µm and 0.45µm pore sizes. The 0.20µm filters remove the smallest particulates whilst the 0.45µm filters are designed to remove particulates which would be detrimental to most analytical columns.


Pre-filters (page 6) have a glass microfibre membrane which is chemically inert and resists most solvents. Q-Fil glass microfibre pre-filters are recommended for removing large particulates from the sample and are ideal for dissolution tests.

Glass microfibre membranes are also available mounted before the microporous filter membrane in the polypropylene housing. The glass pre-filter removes the larger particulates and prevents premature clogging of the filter.

 

CONTACT US  

Tel:        +44 (0) 151 649 4000  

Web:     www.greyhoundchrom.com  

Email:   marketing@greyhoundchrom.com  

FOLLOW US  

Facebook Icon Twitter Icon Instagram Icon LinkedIn Icon   

YOU MAY ALSO BE INTERESTED IN OUR NEWSLETTER  

SIGN UP HERE  

Greyhound Monthly Newsletter  

CATALOGUE DOWNLOADS  

Greyhound Q-Fil catalogue  Greyhound reference standards guide Greyhound Zpure Catalogue  Trajan GC Supplies catalogue

 Greyhound Chromatography Q-Range Vials Catalogue Image  Wellington Laboratories Catalogue 2021-2023   Chem Service Catalogue Image  Chem Service Pesticides Catalogue Image