APH65EB - AZURA Pump P 6.1L (biocompatible)HPG with 10 ml pump head (ceramic), degasser, mixer (250 µl)
General information
Max. flow rate: 10 ml/min
Flow rate range: 0.001–10 ml/min
Flow rate increment: 0.001 ml/min
Maximum delivery pressure: [psi] 5800 psi
Maximum delivery pressure: [MPa] 40 MPa
Maximum delivery pressure: [bar] 400 bar
Pump head materials: Ceramic
Gradient:High pressure gradient (binary)
Leak Management: Yes
Wetted materials: sapphire, ruby, ceramic, PEEK, UHMW PE, FFKM
Pump features: Active pulsation compensation, RFID for automatic pump head detection, Integrated pressure sensor, Purge valve (manual), Leak management, Piston seal wash
Detailed information
Best working conditions: 0.1 - 8 ml/min ml/min
Continuous working conditions: 0.1 - 4 ml/min
Flow rate accuracy: ± 0.25 %
Flow rate accuracy conditions: measured at 5–80 % of flow range, using ethanol
Flow rate precision: ≤ 0.04 % RSD or 0.008 min SD (whichever is greater)
Flow rate precision conditions: based on the retention time at constant room temperature
Gradient range: 0–100 %
Gradient range (recommended): 5 - 95 %
Gradient accuracy: ± 0.3 % at 1 ml/min, 150 bar (ethanol/caffeine tracer) ± 1 % (5 - 95 %, measured at 0.1 – 10 ml/min, water/caffeine tracer)
Gradient precision: < 0.1 % RSD at 1 ml/min, 0.3% RSD overall, based on retention time at constant room temperature
Gradient minimum increment: 0.1 %
Mixing volume: 250 µl
Delay volume: 310 µl with 250 µl Mixer
Pump type: Binary analytical HPLC pump with degasser
Degasser: Yes
Solvent selection valve: 2 x 2 channels
Pulsation: < 2 % Amplitude (typically: < 1.3 %) or < 3 bar (0.3 MPa), whatever is greater, at 1 ml/min ethanol, at all pressures > 10 bar (1 MPa, 147 psi)
Pulsation compensation: Active pulsation compensation
Active piston seal wash: Yes
Piston seal washing: Yes
System protection: Soft start, Pmin und Pmax are programmable
Pump Outlet thread: Female UNF 10-32 (coned)
Pump head inlet (standard): UNF 1/4-28 Thread (flat bottom)
Pump head outlet (standard) UNF 10-32 Thread
Leak Sensor: Yes `
Communication
Interfaces: LAN, Pin header connectors (Analog IN, Start In, Error IN)
Control: LAN, Analog and event control, Mobile Control
Analog inputs: Flow rate, 0–10 V via pin header connectors
Analog outputs: 8 event outputs (TTL, OC, Relais) and 24 V
General
Power supply: 100 - 240 V; 50 - 60 Hz Maximum power consumption 100 Watt
Dimensions: 361 mm x 208 mm x 523 mm (W × H × D)
Weight: 14.1 kg
Ambient conditions: 4–40 °C (39–104°F) Air humidity: below 90 % humidity, non condensing
The AZURA® Pump P 6.1L uses technology to overcome the challenges of pumping LC solvents at high pressure and defined flow rates. This pump is designed to fulfill the needs for either high pressure or low pressure gradient forming. The pump can deliver flow in the range of 0.001–50 ml/min at pressures up to 1000 bar (depending on model). The AZURA® binary pump contains two identical high pressure pumps, a 2×2-channel inlet solvent selection valve and the low-volume AZURA® mixer. The AZURA® quaternary pump contains one high pressure pump and an integrated LPG mixing block with a 4-channel inlet solvent selection valve and a low-dwell volume AZURA® mixer. The integrated degasser and AZURA® inline filter are completing this analytical AZURA® P 6.1L HPLC pump and turn it into a work horse in the lab. This pump is also available with wetted materials made from ceramic, PEEK and titanium for biocompatible applications.